condensation that may have formed, both inside the unit and in the external water
collection tray. The natural defrosting time can vary from a few minutes to several
hours. In the wintertime and when the refrigerator is shut off, the door should be left
slightly ajar for ventilation and all power disconnected.
Draining and Condensation
Isotherm refrigerators are supplied with a drainage tube directly connected to the
unit, Fig. 7. Unwind the drainage tube and connect it to an appropriate discharge,
Fig. 8.

3.1 Low voltage protection

In order to prevent excessive battery depletion, a protection device shuts off the
compressor in case of insufficient voltage and turns it back on when the voltage in
the system increases after the batteries have been charged.
System Voltage
12V
24V
If the bridge is removed between C and P, the values indicated in the parentheses are
valid.
WARNINGS: Before switching on the unit, always make sure that the
batteries are in optimal condition.
46
Shut-down
Minimum Operating
Voltage
Voltage
9.6 (10.4) V
10.9 (11.7) V
21.3 (22.8) V
22.7 (24.2) V
User Manual