AC/DC VOLTAGE (LESS THAN 600V)
1. Insert RED test lead into VΩ jack
COM jack
Voltage
display.
2. Apply test leads to the circuit to be tested to measure voltage.
The meter will auto-range to display the measurement in the
most appropriate range.
NOTE: If "–" appears on the LCD, the test leads are being applied to
the circuit in reverse. Swap the position of the leads to correct this.
NOTE: When in a voltage setting and the test leads are open,
readings of order mV may appear on the display. This is noise and
is normal. By touching the test leads together to close the circuit
the meter will measure zero volts.
NOTE: To access mV range for V AC
must be used.
NOTE: When voltages in excess of 25V AC or 60V DC are
measured, the Hazardous Voltage Indicator
display.
OPERATING INSTRUCTIONS
, and rotate function selector switch
4
or AC Voltage
Black lead
, and BLACK test lead into
5
setting. Note "DC" or "AC" on the
Red lead
OR
the "RANGE" button
will appear on the
to the DC
2
7
9