8 Commissioning

The EduTrainer
®
The circuit is inserted and assessed with safety laboratory cables. For operation on grid voltage, ensure that
the supply voltage is not short-circuited by the switch, as this can destroy the switch.

9 Function

The ballast unit built into the EduTrainer
Before the power reduction is activated, the lamp must be operated at 100% power for at least 10 minutes.
Type of power
reduction
DALI bus
StepDIM
AstroDIM
30
is connected to the corresponding supply unit when the power supply is disconnected.
Warning
The device must only be operated on a current-limited feed unit. Maximum backup
fuse 10 A(T).
The device may only be operated with a connected PE conductor.
Warning
Electric shock may cause potentially lethal injuries. The device must only be
operated with correctly used and undamaged lamps.
®
Control/connections
Via external DALI controller
/ DA, DA
Via control cable
/ SD
Via internal timer element
/ SD
offers 3 different ways of reducing the power:
Area
Activation
100% ... 70%
As soon as a DALI command is sent to the EBU. Takes priority
over other dimming functions.
100% or 70%
When the voltage is switched on at the "SD" connection
Dimming time: 420 s
Min 1 s after the EBU is switched on.
100% or 70%
When the voltage is switched on at the "SD" connection and
the EBU is switched on at the same time
Dimming time: 420 s
(e.g. bridge between "AC(L)" and "SD").