10. Universal rubber cones
11. Hose (thin)
12. Cooling water hose
13. Cooling water hose connection
3.1 Manual for cooling – vacuum - set
Please remove the water out of the cooling system as completely as possible.
Assemble and adequate adapter to the cooling water tank. (photo 5)
Hang the radiator vacuum device to the hood in order that the cooling adapter
connection no. 9 extends to the cooling water tank.
Connect the cooling adapter hose no. 9 to the adapter.
Check and make sure that all switches are in „OFF" position.
Connect the thin hose no. 11 to the connector no. 6 and the cooling water hose no.
12 to the cooling water hose adapter no. 8.
Connect the compressed air line to the compressed air connection no. 4, then press the
button no. 5 to "ON". Then open the stopcock for air no. 3 (see photo 6)
Close the stopcock for air no. 3 when having reached a negative pressure
of -0,6 ~ -0,8 bar. (see photo 7)
If there is only insuffi cient vacuum generated, please check fi rst the input pressure. Then
press the button no. 5 to „OFF".
3.2 Refi lling of the cooling water
Before refi lling the cooling water, please make sure that the stopcock for air no. 3 is
closed.
Open the stopcock for cooling water no. 7 in order that the coolant can be sucked into
the cooling system (see photo 8)
The process is terminated when the pointer returns to the „ZERO" position.
4. List of radiator adapters and photos: