How to stick the gasket:
The gasket supplied with the hob avoids all infiltration of liquids in the cabinet.
His installation has to be done carelessly, in conformity of the following drawing.
ELECTRICAL CONNECTION
The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
Protection against the parts under tension must be ensured after the builting-in.
The data of connection necessary are on the stickers place on the hob casing near the
connection box.
The connection to the main must be made using an earthed plug or via an omnipolar circuit
breaking device with a contact opening of at least 3 mm.
The electrical circuit must be separated from the network by adapted devices, for example :
circuit breakers, fuses or contactors.
Mains
Connection
230V~1P 50Hz
1 Phase + N
400V~2P 50Hz
2 Phases + N
( * ) calculated with the simultaneous factor following standard TN 60 335-2-6/1990
Caution !
This appliance has only to be connected to a network 230 V~ 50 Hz
Connect always the earth wire .
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover
use a medium screwdriver. Place it in the slits and open the cover.
Stick the gasket (2) two millimeters
from the external edge of the glass,
after removing the protection sheet (3).
Cable diameter
Cable
3 x 2.5 mm²
H 05 RR 25 A *
4 x 1.5 mm²
H 05 RR 16 A *
27
Protection calibre