Selection of functions
1 ON
Automatic closing enabled; (1 OFF - disabled)
2 ON
"Open-stop-close-stop" function with button (2-7) and radio control (AF board inserted) enabled;
2 OFF
"Open-close" function with button (2-7) and radio control (AF board inserted) enabled.
Adjustment Trimmer
E
Trimmer T.R.2M. = Adjustment delay during closure of 2nd motor (min.1", max.10").
Trimmer T.L. = Adjusts of operating time (min.15", max.120").
(Note: the "operator present" function is activated by setting the operating time to the minimum).
Trimmer T.C.A. = Adjusts automatic closing time (min.0", max.120")
Motor torque limiter
To vary the motor torque, move the indi-
cated faston to one of the four positions:
1=min, 4=max
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.