Master Plumber 539892 Manual Del Usuario página 3

Bombas de chorro cloacales y para aguas residuales
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Safety / Performance / Installation
READ AND FOLLOW
SAFETY INSTRUCTIONS!
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one
of the following signal words and be alert to the potential
for personal injury:
warns about hazards that will cause serious
personal injury, death or major property
damage if ignored.
warns about hazards that can cause serious
personal injury, death or major property
damage if ignored.
warns about hazards that will or can cause
minor personal injury or property damage if
ignored.
The label NOTICE indicates special instructions which are
important but not related to hazards.
Carefully read and follow all safety instructions in this
manual and on pump.
Keep safety labels in good condition.
Replace missing or damaged safety labels.
1. Read this manual carefully. Failure to follow these
Instructions could cause serious bodily injury and/or
property damage.
2. Check your local codes before installing. You must
comply with their rules.
3. Vent sewage or septic tank according to local codes.
4. Do not install pump in any location classified as
hazardous by National Electrical Code, ANSI/NFPA
70-1990.
Hazardous voltage, Can shock, burn or
cause death. During operation, the pump is
in water. To avoid fatal shocks, proceed as follows if
pump needs
servicing:
Risk of electrical shock. Can burn or kill.
Do not lift pump by power cord. See "Cord
Lift Warning" on Page 5.
5A. Disconnect power to outlet box before unplugging
pump.
PERFORMANCE
Model
5 (1.5m)
539892
3180(12,038)
540056
3900(14,763)
For parts or assistance, call Master Plumber Pump Customer Service at
GPH (LITERS) AT DISCHARGE FT. OF HEAD
10 (3m)
15 (4.6m)
2700(10,221)
2100(7,949)
2550(9,653)
960(3,634)
5B. Take extreme care when changing fuses. Do not
stand in water or put your finger in fuse socket.
5C. Do not modify cord and plug. When using cord and
plug, plug into a grounded outlet only. When wiring to
a system control, connect pump ground lead to sys-
tem ground.
6. Do not run pump dry. Dry running can overheat pump,
(causing burns to anyone handling it) and will void
warranty.
7.
Pump normally runs hot. To avoid burns when servic-
ing pump, allow it to cool for 20 minutes after shut-
down before handling it.
8. In normal service, motor should not need oiling.
Motor has been filled at the factory with a special oil.
INSTALLATION
NOTICE: Install pump on a hard, level surface (cement,
asphalt, etc.). Never place pump directly on earth, clay or
gravel surfaces.
Piping – Effluent Applications
(3/4" or Less Solids)
Piping must be 1-1/2" minimum to carry volume of pump
discharge. Check local codes to determine if a check
valve is required in your system. In cold climates, check
valves are not used to prevent effluent from freezing in
piping.
If using as a sump pump, a check valve is recommended.
Piping – Sewage Applications
(2" or Less Solids)
In any case, piping must not be smaller than pump
discharge.
When installed in a sewage system, pipe must be capable
of handling semi-solids of at least 2" (5.1 cm) diameter.
The rate of flow in the discharge pipe must keep any sol-
ids present in suspension in the fluid. To meet minimum
flow requirements (2 feet (.6 m) per second in discharge
line), size pipe as follows:
A Pipe Size Of:
1-1/2" (3.8 cm)
2" (5.1 cm)
2-1/2" (6.3 cm)
3" (7.6 cm)
20 (6.1m)
25 (7.6m)
1500(5,678)
750(2,839)
1-800-628-9439
Will Handle a Flow Rate Of:
12 GPM (45 LPM)
21 GPM (79 LPM)
30 GPM (113 LPM)
48 GPM (181 LPM)
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

540056

Tabla de contenido