10 - Capacity check / LED messages
The remaining capacity of the BEKAONE120 is indicated on the LED display after each normal
lubrication cycle (see graphic and table). To check the remaining capacity explicitly, activate an
intermediate lubrication.
Filling
Remaining
capacity
cycles
> 600 cm
600 cm - 481 cm
480 cm - 361 cm
360 cm - 241 cm
240 cm - 121 cm
< 120 cm
LED messages
LED
Status
ON
green
Flashes every 60 s
Flashes 2x shortly
every 10 s
red
Flashes every 10 s
-29-
Remaining
reservoir discharges
(complete reservoir)
3
3
3
3
3
3
3
3
3
3
Cause
Function control (=ok), device is activated
Backpressure
is too high
Max. number of cycles
is reached
Low battery
EN
Possible
lubrication pulses
(cycles)
> 2500
2500 - 2001
2000 - 1501
1500 - 1001
1000 - 501
< 500
Device is currently lubricating
Unscrew the device, switch it off and on:
- Pump is running → check the lube point for too high backpressure →
correct error → screw the device in again
- Device does not work → replace the device
Replace the device
Example: 5 filling cycles
(>4 remaining reservoir
discharges)
Troubleshooting