Active Periodic Cooling (APC) function behavior at
"cooling for a set ( clS)" mode given in the graph for
below parameters .
APC Parameters
Cooling mode
Cooling start time
Cooling cycle
Cooling set point C ( set –adjusted data)
Cooling set point F ( set –adjusted data)
Waiting time in cooling set point
Max cooling time
Humidification*
Humidification Time*
Max humidity during humidification*
Cooling fan activation**
* only for models equipped with humidifier
**only for models equipped with cooling fan
System repeats APC behavior every cPr time.
In a power outage, cooling cycle time cPr is not
reset, It will continue from last recorded time.
Example: if there is an 1 hour power cut, the next
cooling time will delay about 1 hour.
Remaining time to next cooling can be checked by
the controller ( see page 9)
Display
settings
clF
clS
cb
on
cPr
24 h
cSt
-8.0 C
FSt
-15 F
cth
20 min
hct
120 min
chu
on
cht
10 min.
chh
80 RH%
cFn
on
APC starts
cSt / FSt
APC stops
cth
APC start
cht
Humidification starts
21
TEMPERATURE
APC stop
chh
HUMIDITY