REQUIRED DAILY CHECKLIST
 Disconnect the air supply from the tool and remove all
fasteners.
 Check all screws, nuts, bolts, and pins on the tool. If
any of these are loose, they must be tightened with the
appropriate size wrench.
 Press the workpiece contact against a workpiece to
ensure that it moves smoothly.
 With the workpiece contact depressed, pull the trigger.
The trigger should move smoothly, without binding.
 While the tool is not loaded, connect the appropriate air
supply (at 70 psi) to the tool.
 Without pulling the trigger, press the workpiece contact
against a workpiece several times. The tool must not
operate. No air should leak from the tool.
To order parts and maintenance kits, call 1-800-525-2579.
Overhaul Maintenance Kit ................................................................................................................................079077005701
Driver Maintenance Kit .....................................................................................................................................079077005702
Driver Assembly Kit ..........................................................................................................................................079077005703
Trigger Valve Assembly Kit ...............................................................................................................................079077005704
Oil and Wrench Kit............................................................................................................................................079077005705
WARNING:
Current attachments and accessories available for use with this tool are listed above. Do not use any attachments or
accessories not recommended by the manufacturer of this tool. The use of attachments or accessories not recommended
can result in serious personal injury.
MAINTENANCE
 With the workpiece contact not engaged on the
workpiece, point the tool down and away and pull the
trigger several times. Hold the trigger in this position for
a minimum of 5 seconds. The tool must not operate.
 Press the workpiece contact firmly against the workpiece.
Pull the trigger. The tool must operate.
 With the workpiece contact still depressed, release the
trigger. The driver must return to its up position.
 If the tool successfully meets all the requirements in this
checklist, it is ready for use. Load the proper fasteners
for the desired application.
 Set the depth of drive according to the Drive of Depth
Adjustment section in this manual. Repeat this checklist
before using the tool each day, or if the tool is dropped
or damaged in any way.