Paragraph 4 – Proportional to External Impulses (multiplication)
Programming
Display during Operation
Operating mode
1:n = impulse
multiplication
Alarms and statuses
Lev = Level alarm
Mem = Memory alarm
Paragraph 5 – Proportional to External Impulses (division)
Programming
Display during Operation
Operating mode
n:1 = impulse
multiplication
Alarms and statuses
Lev = Level alarm
EM00136592
The pump doses in proportion to an external signal (i.e.: impulse launch
counter). With every signal received, the pump makes the programmed
"n" number of strikes. The pump automatically sets the dosage
frequency, adapting it to the time that passes between two successive
signals. It is possible to set the time (timeout) in seconds, beyond which
the pump resets the interval count in order to avoid dosages over
excessively long times. The pump has a memory function, which signals
the reception of a signal during dosage. If set to Off, it merely sends a
signal, if set to On it sends a signal and memorizes the impulses, then
executes them when it has finished receiving signals.
The value of "n" can be modified during operation, by pressing the
keys to decrease it.
Memory
function
status
1:n
M
1
Lev
Stop
0
Pump status
Empty = pump in start
Stop = pump stationary
Pause = pump in pause
The pump doses in proportion to an external signal (i.e.: impulse launch
counter). At every "n" signal, the pump makes a strike. You can set the
value of "n" during programming. By programming the value of "n" you set
the maximum dosage %. This value can be modified during operation, by
pressing the
n:1
4
Lev
Stop
P100%
Pump status
Empty = pump in start
Stop = pump stationary
Pause = pump in pause
rev. 1.0
Operation
keys at the same time to increase the flow, or the
Programmed
value of n
Current dosage value
Displays stroke
countdown
Operation
keys at the same time to increase the flow, or the
keys to decrease it.
Display during Setting (MODE key)
Programmed
value of n
n:1
n=6.00
Current dosage value
Maximum dosage
percentage
Effective value
of "n"
EN
Display during Setting (MODE key)
Displays programmed
timeout
Timeout
60s
Current dosage value
Displays the value of n. This
can be modified by pressing the
+ or – keys at the same time
Operating mode
6
Programmed value
• Value of n
P100%
Current dosage value
• The dosage % can be modified by
pressing the + or – keys at the
same time
n
1
8