By PUMA 1HP and 1/2HP compressor, LEONARDO 1HP compressor, AIRCRAFT 1HP compres-
12.5 Connecting KONTAKT 155/R Green Line new to Pressurisation with a Classic CO
Bottle (Two-Tap Device):
1. Beverage inlet
2. CO
outlet
2
3. Pressure control
4. Keg coupler (A-system, S-system,
M-system)
13. CONNECTION AND REGULATION OF KONTAKT 155/R Green Line new WITH
CO
PRESSURE BOTTLE
2
1. Screw speed fittings onto the keg coupler.
2. Plug 3/8" and 5/16" hoses into the speed fittings on the keg coupler.
3. Connect the 3/8" and 5/16" hose with the speed fittings located on the cooler in accord-
ance with the description found on the label above the speed fittings.
4. Screw the high pressure hose onto the CO
5. Fit the keg couplers onto the beverage keg, but leave the keg coupler in closed position
(top position).
6. Open the valve on the CO
set the desired pressure for both the separate beverage lines. (The set pressure is displayed
20
on the pressure gauges located on the front of the cooler).
7. Tap the keg using the keg coupler.
WARNING: Check that all joints are sufficiently leak-tight after connection.
If everything is in order, check the thermostat settings (in off position). Connect the cooler to the
power mains. Then use the keg coupler to tap the keg, set the desired pressure (1.0-3.4 bar) and
use the tap lever to pour out some of the beverage. If the cooler contains remnants of sanitation
solution or water, keep the tap lever in open position until only beverage pours out of the tap.
Set the desired beverage temperature on the thermostat.

14. HOW TO WORK WITH SPEED FITTINGS

14.1 Speed Fitting Installation
Grasp the speed fitting and insert the hose all the way inside the speed fitting body (ca. 20 mm).
The end of the hose must be straight so that it plugs fully into the coupling. If the hose will not go
in, moisten the end of the hose.
Other Pressurisation Options
sor, classic Biogon, N2 bottles.
:
(see Fig. 13.)
bottle using a flare nut.
2
bottle and use the regulating screws on the top of the cooler to
2
(see Fig. 14.)
5. F 5/8 x 9.5 mm speed fitting
6. F 5/8 x 8 mm speed fitting
7. High-pressure hose with W 21.8 flare
nut; pressurised bottles with a G3/4
thread require an adapter for K 115/R
8. Beverage
: