LUTZ B2 Vario Serie Manual De Instrucciones página 13

Ocultar thumbs Ver también para B2 Vario Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
Table 1
Pump
Immersion depth
Delivery rate max.
1)
Delivery head max.
1)
Max. temperature of the
liquid being pumped
Max. viscosity
of the liquid
Max. density of the liquid
All parts coming into
contact with the medium
are made of:
Measured with water at 0 °C
1)
Table 2
Motor
Lutz B2 Vario
220-240V/50Hz
Voltage
Frequency
Power
Rated current
Protection class
Type of
protection
Absolute
 up to 5 g/m³
humidity
Continuous
sound pressure
level
Acceleration due
to vibrations
Lutz B2 Vario PP 32-SL
500 mm
700 mm
75 l/min
7 m wc
-15 °C up to +50 °C
300 mPas
1.3 kg/dm³
PP, PVDF, Hastelloy C, Viton,
PTFE, ETFE
Lutz B2 Vario
220-240V/60Hz
0-40 V
0-40 V
50 Hz
60 Hz
00 W
00 W
0.9 A
0.9 A
II
II
IP4
IP4
 up to 5 g/m³
< 70 dB(A)
< 70 dB(A)
< .5 m/s²
< .5 m/s²
Lutz B2 Vario SS 28-SL
1000 mm
500 mm
stainless steel (1.4571), Viton,
Lutz B2 Vario
Lutz B2 Vario
100-110V/50Hz
100-110V/60Hz
100-110 V
100-110 V
50 Hz
160 W
160 W
1.7 A
II
IP4
 up to 5 g/m³
 up to 5 g/m³
< 70 dB(A)
< 70 dB(A)
< .5 m/s²
< .5 m/s²
GB
700 mm
1000 mm
68 l/min
6.5 m wc
-15 °C up to +90 °C
300 mPas
1.3 kg/dm³
PTFE, ETFE
Lutz B2 Vario
110-120V/60Hz
110-10 V
60 Hz
60 Hz
180 W
1.7 A
1.7 A
II
II
IP4
IP4
 up to 5 g/m³
< 70 dB(A)
< .5 m/s²
13