cleanAIR Verus air Manual De Usuario página 8

Ocultar thumbs Ver también para Verus air:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
Limitations on use of CleanAIR® Verus air
Never use the helmet in the following envi-
ronments and under the following conditions:
• if oxygen concentration in the environment is
lower than 17 %,
• in oxygen-enriched environments,
• in explosive ambience,
• in environments that represent an immediate
threat to the life and health.
The helmet does not protect against hard
shocks, explosions or corrosive substances.
Do not use in environments where the user
does not know the type of contamination or its
concentration.
Do not use when the powered air purifying
respirator is turned off or when the compressed
air inlet is closed! In this case the respiratory
system gives little or no respiratory protection.
Also there is a risk of a high concentration of
carbon dioxide (CO
) building up and of oxygen
2
deficiency occurring inside the helmet.
Move to a  secure location and take appropriate
measures when any of the following problems
occur while using the helmet:
• if the PAPR or the compressed air system
cease to operate for any reason whatsoever,
the user must leave the contaminated
workplace without delay,
• if you experience stench or irritation or an
unpleasant taste while breathing.
• if you feel unwell or if you experience nausea.
Filters designed for capturing solid and liquid
particles (particle filters) do not protect the
user against any gases. Filters designed for
capturing gases do not protect the user against
any particles. In the workplace contaminated by
both types of pollution, combined filters must be
used.
3. Control, maintenance and spare
parts replacement
CleanAIR® Verus is a complete welding helmet
consisting of the welding shield including auto-
darkening filter and headband. Version CleanAIR®
Verus air has additional air distribution. The
lifetime of the helmet and visors is influenced
by many factors such as: cold, heat, chemicals,
sunlight or incorrect use. The helmet should be
checked on a daily basis of possible damage of
its inside or outside structure.
Careful use and correct maintenance of the
welding helmet enhances operating life and
improves your safety!
2
Cleaning:
• After each work shift, clean the head section,
check individual parts, and replace damaged
parts.
• Cleaning must be performed in a room with
sufficient ventilation. Avoid inhalation of
harmful dust settled on individual parts!
• For cleaning, use lukewarm water (up to +40
°C) with soap or other non-abrasive detergent
and a soft brush.
• It is prohibited to use cleaning agents with
solvents.
• After cleaning individual parts with a damp
cloth, it is necessary to rub them dry or let
them dry at room temperature.
• It is recommended to use CleanAIR® Klar-pilot
fluids for caring of the visors and plastic parts.
• Do not use dishwasher or dryer!
ADF settings/adjustment
ON/OFF
• The welding filter switches on automatically
when an intense light source is detected.
• Press any button to check if the lens is working
properly and to activate Mode adjustments.
SHADE CONTROL (*PICTURE 1)
• Press the „M" button (7), until the mode
indicator is on Shade (3), the LED screen (6)
now shows the current shade number
• Press „+" button (8) and „-" button (9) to set
the desired shade number.
• To toggle between the two shade ranges 5-8
and 9-13, press and hold any button „M"(7),
„+"(8),"-"(9) for 3 seconds.
• Once the range is switched use „+" (8) and „-"
(9) button to set the desired shade.
DELAY CONTROL
• Press the „M" button (7), until the mode
indicator is on Delay(4), the LED screen (6)
now shows the current delay setting.
• Press „+" button (8) and „-" (9) button to set
the desired delay setting. Delay time can be
adjusted from 1 (0.1Seconds)-9 (0.9 Seconds).
SENSITIVITY CONTROL
• Press the „M" button(7), until the mode
indicator is on Sensitivity(2), the LED screen(6)
shows the current sensitivity setting.
• Press „+" button (8) and „-" button (9) to set
the desired sensitivity level. Sensitivity can
be adjusted from 1 to 9. Higher number means
higher sensitivity.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Verus70 30 0140 30 01

Tabla de contenido