MAV SERIES
AMPLIFIER
6. CONNECTION
6.1. AC MAINS CONNECTION
Please, make sure that AC mains match with equipment voltage specifications.
Use the equipment power cord to connect it to AC mains.
The unit is factory set to be supplied at 110~230 Vac 50~60 Hz. Voltage switching is automatic.
For your own safety never disconnect or disable the grounding of any equipment.
If the outlet doesn't have ground connector, you must use an adapter to ground the third cable
properly. In order to prevent electrocution or fire, make always sure that the amplifier and all
associated equipment are properly grounded.
6.2. LINE INPUTS
The unit has 6 audio inputs with different audio levels.
MIC1: Jack stereo connector, Vox control. MIC level.
MIC/LINE2: XLR connector. MIC/LINE level selectable. Phantom selectable.
MIC/LINE3: XLR connector. MIC/LINE level selectable. Phantom selectable.
MIC/LINE4: XLR connector. MIC/LINE level selectable. Phantom selectable.
LINE5: RCA connector. LINE level.
LINE6: RCA connector. LINE level.
EMC: RCA connector. VOX control. LINE level.
6.3. LINE OUTPUT
Unit includes an audio line OUT with two RCA connectors. This output broadcasts the audio of the
whole system, general and priority inputs, and it is not affected by Master Volume control.
MAV SERIES Version 1.0
Page 8 of 13