6.4. PRIORITY  
Unit has four priority levels. 
Priority 1 (max.): EMC input, activated by VOX control. It activates all zones. 
Priority 2: PMV‐6Z. It activates selected zones. 
Priority 3: MIC1, activated by VOX, it is broadcasted to front panel selected zones. 
Priority 4: MIC2 = MIC3 = MIC4 = LINE 5 = LINE6. 
6.5. 100 V LINE SPEAKERS 
Connect the speakers in parallel. The sum in W of all speakers connected to the amplifier must not 
exceed its power, 120 W for MAV‐120Z6, 240 W for MAV‐240Z6 and 500 W for MAV‐500Z6. 
 
 
NOTE: Each line is independent, never mix two lines. The minimum section is 1.5 mm², but it can be 
increased according to the installation requirements. 
6.6. FRAME TO GND LINK 
This amplifier includes a ground to frame link switch. A single frame to ground link should exist in 
the installation; in other case ground noise could appear. Place the switch in the GND position to 
join frame and ground or in the LIFT position to separate them. 