Descargar Imprimir esta página

Gewiss GW 20 982 Manual Del Usuario página 3

Modulo di uscita rf per comando motore

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

DESCRIPTION
______________________________________________
The output module for motor control is used, via two relay outputs, to actuate radio controls coming
from:
• remote controls,
• button pads,
• conventional inputs modules.
C
AUTO key
Multifunction and AUTO func-
tion display LED
ON1 activation green
signal LED
B
Local control keys
ON2 activation green
signal LED
The motor control module is provided with a three-colored (yellow/red/green) multifunction LED (A) to
show the operating mode and a pair of buttons on the front (B) for local control of the output relays.
A button (C) is used to enable the AUTO function, which is signaled by the lighting up of a green LED
(D). The AUTO function enables management of the module by automatic control devices (sensors,
timers, etc.) connected to conventional input modules (configured in STATUS mode). The wire entry
is used to connect the potential-free contacts of 2 traditional N.O. buttons or a double arrow. The
modules are powered at 230V. The module's output contacts are live. A rotary switch is used to select
the configuration mode and the operating time of the device.
1
0
9
When the motor control module is powered up, the outputs to terminals 3 and 4 are not powered.
After a power cut the AUTO function returns to the status that was enabled before the interruption.
CONFIGUR TION
__________________________________________________
Learn configuration
All that is required to associate a motor control module to one or more devices is to turn the switch to
position 0: the multifunction LED becomes fixed red.
At this point the device that it is intended to combine must be set up according to the description in the
relative instruction sheet, so as to generate the required control message: the multifunction LED will go
out for about 5 seconds and then light up again (red) awaiting a possible further combination.
A maximum of up to 16 control channels can be associated to each module.
Should the maximum possible number of associations be reached, the LED becomes blinking red; in
this case it is not possible to make any further associations.
Cancel configuration
Turn the switch to position 9 to cancel all the combinations made: the multifunction LED becomes
blinking yellow to show that the operation is in progress.
The fixed yellow LED shows that the operation has been completed.
OPER TION
______________________________________________________
The module controls the two output relays depending on the radio control received.
In general, the output contact at terminal 3 of the module is closed on receipt of an "up/forward"
command (ON1) and the output contact at terminal 4 is closed on receipt of a "down/back" command
(ON2). A stop command (OFF) causes both output contacts to open (terminals 3 and 4).
A maximum time limit is provided after closing a contact after which the module performs a stop
command.
The timed value is determined by the rotary switch.
1
N
230V 50Hz
2
L
A
8A 250V
3
4
3A 250V
D
Cables:
Red
White
Orange
red
white
orange
4
3
2
L
0 - learn configuration
1 - 30 sec timed operation
2 - 60 sec timed operation
3 - 90 sec timed operation
4 - 120 sec timed operation
5 - 180 sec timed operation
6 - not used
7 - not used
8 - not used
2 3
9 - cancel configuration
4
5
6
8
7
The module is typically used to control the motor of a sun blind or a roller blind:
• in combination with an RF button pad, for example, the blind is raised by pressing the upper part
of the key of the channel associated to the module and lowered by pressing the lower part. It is
stopped by pressing either the upper or lower part of the key when the blind is in motion.
L
N
M
4
3
ON1
Common
ON2
In the same way the same operation is obtained by combining the module with a channel of a remote
control or with a conventional inputs module, in combined inputs mode, connected to an interlocked
double button.
1
N
Other operating modes are provided:
• in combination with a conventional inputs module, configured in status mode, connected to a
twilight sensor, the roller blind is raised and lowered at the intervention of the sensor. This
automatic operating mode must be explicitly enabled using the module's AUTO button. The green
LED is lit when the function is enabled;
• in combination with a conventional inputs module, configured in ON or OFF mode, will give,
respectively, the "on/forward" or "down/back" command when the contact is closed. The stop
command is given when the time set in the module elapses.
SIGN LS
____________________________________________________________
MULTIFUNCTION LED
Learn configuration
Device waiting to learn a command: the LED becomes fixed red.
Max. number of combinations reached: the LED becomes blinking red.
Cancel configuration
Combination cancellation in progress: the LED becomes blinking yellow.
Cancellation complete: the LED becomes fixed yellow.
Regular functioning
Charge powered up (at least one output contact closed): the LED becomes fixed green.
AUTO LED
Automatic operation enabled: LED on.
INST LL TION
The output modules have inset installation, using the special System series supports. The protection
level can be maintained, even for installations other than inset (e.g. in junction boxes) by using the
terminal cover.
Terminal cover
TECHNIC L D T
- Operating temperature
- Radio frequency
- Radio range
- Supply
- Dimensions
M
2
1
L
N
______________________________________________
____________________________________________
ENGLISH
-5° +40°C
868 MHz
100 m in a free field
230V - 50Hz
2 System modules
3

Publicidad

loading

Este manual también es adecuado para:

Gw 21 982