C h e c k i n g
o f
l a m p
The lamp cartridge must be replaced after 1000 hours of usage.
When 1000 hours have elapsed the STATUS indicator will light in
red (see page 32). Periodically check the hours of lamp usage in the
menu so that you will have time to purchase a new lamp cartridge
before the old one burns out.
1 Press MENU to display the main menu.
2 Press the cursor / keys to select "POWER MENU."
3 Press L-CLICK to display the POWER MENU.
4 Press the cursor / keys to select "LAMP USAGE."
The lamp usage hours will be displayed.
Resetting the lamp usage hours to zero
You need to reset the lamp usage hours to zero after replacing the
lamp cartridge (see page 33).
1 Carry out the steps above.
2 Press POWER ON on the remote control for more than
ten seconds.
"LAMP USAGE" will be reset to zero and the STATUS
indicator will go off (see page 32).
If the unit doesn't turn on because lamp
usage exceeds 1100 hours.
The unit is designed not to turn on after the lamp usage has
exceeded 1100 hours. (If the unit is in use, it will go off.) If this
happens you must replace the lamp cartridge with a new one
immediately. After replacing the lamp cartridge, you need to reset
the lamp usage hours to zero to enable you to turn on the unit.
1 Connect the power cable (see step 1 on page 15).
2 Press POWER OFF on the remote control for more ten
seconds.
"LAMP USAGE" will be reset to zero and the STATUS
indicator will go off (see page 32).
All manuals and user guides at all-guides.com
h o u r s
u s a g e
E – 30
R e s e t t i n g
f a c t o r y
s e t t i n g s
The following items can be reset to the standard settings.
• H POSITION
• V POSITION
• PICTURE ADJ
• FINE PICTURE
• BRIGHTNESS
• CONTRAST
• COLOR
• TINT
• SHARPNESS
• WHITE BALANCE
Although the above items for the particular input source are stored
in memory when setting the value, the items for all input sources
will be reset regardless of the input source when resetting.
1 Press MENU to display the main menu.
2 Press the cursor / keys to select "SETTING MENU."
3 Press L-CLICK to display the SETTING MENU.
4 Press the cursor / keys to select "RESET."
The horizontal frequency appears under "RESET" when
the present input source is RGB.
5 Press the cursor + key for more than three seconds.
"COMPLETED" appears under the title "RESET" after
the reset is complete.