OPERATING AND REPAIR MANUAL NO.08/13 FOR GKS-PERFEKT
Inspect the twin lifter regularly for damage, in particular its belts and ratchets.
The hydraulic oil must be inspected at least once a year.
The twin lifter must be placed upright for this and the piston rod lowered.
After removal of the rubber seal, the oil (ISO VG 15.22)
is added up to the lower edge of the opening.
Protect the equipment against cold and heat (prolongs the service life).
Annual inspection in accordance with BGV D8
Stable welded structure, 2 hydraulic lift units with manual pump and drain valve, direct wheel steering using
connected steering handle, standard polyurethane wheels, polyamide rollers as alternative.
SCOPE OF SUPPLY
-
two twin lifter halves
-
two lashing straps with ratchet (7)
-
two pump levers
-
one operating manual
-
with spare parts list
Georg Kramp GmbH & Co KG
GKS-PERFEKT
Max-Planck-Str.32
70736 Fellbach/Germany
in terms of Directive 2006/42/EC of the European Parliament and the Council on 17 May 2006,
We herewith declare that the GKS-PERFEKT Type TW28 lifting gear for the internal transport of machines and
heavy loads conforms to the following applicable provisions:
Machinery directive 2006/42/EC
Applicable international technical standards, in particular
DIN EN 1494:2000 Mobile or movable jacks and associated lifting equipment
DIN EN ISO 12100-1:2004 Machine safety
Applicable national technical standards and specifications, in particular
BGV D8 Accident prevention regulations for winches, lifting and towing devices
Equipment Safety Act (GPSG)
Georg Kramp GmbH & Co.KG
Max-Planck-Str.32, 70736 Fellbach
TWIN LIFTER TYPE TW28
MAINTENANCE
TECHNICAL DESIGN
PRODUCTION AND SALES
lifting and transport system
DECLARATION OF CONFORMITY
Annex II A
TEST CERTIFICATE
Tel.: +49 711- 51 09 81 - 0
Fax : +49 711- 51 09 81 - 90
E-Mail: info@gks-perfekt.com
Internet : www.gks-perfekt.com
Fellbach, den 05.07.2013
ppa.Kramp
Page 6