TROUBLESHOOTING
IF THE FILL VALVE: • DOES NOT TURN ON
• WON'T TURN OFF
• WON'T REFILL TANK
REMOVE CAP AND CHECK FOR DEBRIS
A:
Turn off water supply, then flush toilet.
B:
With right hand push float up, grip and
hold shaft under float.
C:
With left hand twist cap and lever arm
counterclockwise to unlock cap. Let cap
hang on float cup.
D:
Hold empty cup upside down over un-
capped valve to prevent splashing.
E:
Turn water supply on and off a few times,
then leave it turned off.
F:
Replace valve cap.
• Place cap assembly on top of gray valve
body by aligning cap arm and adjustment
rod next to refill tube.
• Press down on top cap while rotating top &
arm clockwise to locked position.
See Our Troubleshooting HOW-TO VIDEO
http://bit.ly/2yAdZn7
VIDEO
REPLACE FILL VALVE SEAL
A:
Remove cap (see above).
*
B:
Replace seal with a
genuine Fluidmaster
242 Seal.
C:
Replace valve cap.
• Place cap assembly on top of gray valve body by
aligning cap arm and adjustment rod next to refill tube.
• Press down on top cap while rotating top & arm clockwise to locked position.
*
Always use genuine Fluidmaster parts when installing or repairing. Fluidmaster will not be
responsible or liable for use of non-Fluidmaster parts during installation or repair.
20
All manuals and user guides at all-guides.com
WATER LEVEL IN BOWL IS TOO LOW
A:
B:
C:
D:
Cap
MY FLAPPER STAYS OPEN TOO LONG & I GET A DOUBLE-FLUSH
A:
Seal
WATER FROM REFILL TUBE MUST
FLOW THROUGH OVERFLOW PIPE
Make sure the refill tube is supplying water down
overflow pipe. (Metal side out for refill clip)
WATER LEVEL IN TANK MAY BE TOO LOW
1/2" below top of overflow pipe is recommended
(see page 15).
FLAPPER MAY BE CLOSING TOO SOON
Give flapper chain approximately 1/2" of slack
(small "j" shape).
FILL VALVE DIAL MAY NEED TO BE
ADJUSTED
(see page 18).
ADJUST THE FLAPPER SETTING TO A LOWER NUMBER
(See page17, step 11B.)