Descargar Imprimir esta página

Grohe Roman Tub Combination 25 580 Manual Del Usuario página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

953971.book : I95397US.FM Seite 1 Mittwoch, Juni 17, 1998 3:22 PM
English
25 580
25 582
25 590
25 592
1
Specification
Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Specifications
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure
reducing valve
• Max. operating pressure
[1]
• Test pressure
• Flow delivery, see figs. [1] and [2]
• Temperature
- max. (hot water inlet)
- max. (handshower)
• Water connection
Notes
• An access panel must be provided for access to
diverting unit and pipe connections.
• Installation of backflow protection must comply
with local codes and regulations.
• Major pressure differences between cold and hot
water supply should be avoided.
[2]
7.25 psi
14.5 - 72.5 psi
145 psi
232 psi
176 °F
158 °F
hot - LH
cold - RH

Publicidad