Descargar Imprimir esta página
Lincoln Electric HARRIS Multi-Stage 705 Serie Manual De Instrucciones
Lincoln Electric HARRIS Multi-Stage 705 Serie Manual De Instrucciones

Lincoln Electric HARRIS Multi-Stage 705 Serie Manual De Instrucciones

Publicidad

Enlaces rápidos

Heated Multi-Stage® Compressed Gas Regulators
Régulateurs Multi-Étages® Chaffé, Pour Gaz Comprimé
Reguladores De Calentamiento Eléctrico Multietapa, Para Gases Comprimidos
IMPORTANT
For your own safety, read
these instructions. Failure
to do so could lead to seri-
ous injury.
IMPORTANTE
Por su propia seguridad lea
estas instrucciones. El no
seguir estas instrucciones
podría resultar en lesiones
severas.
Model 705 Series Heated Regulator
Installation and Operation Instructions
USER RESPONSIBILITY
This equipment will perform in accordance with its intended design parameters when
installed, operated and maintained in accordance with the instructions provided. This
equipment must be checked periodically. Defective equipment should never be used.
Parts that are broken, missing, worn, distorted or contaminated, indicate the equipment
should not be used.
This equipment or any of its parts should never be altered. The user of this equipment
shall have the sole responsibility for any malfunction that results from improper use,
faulty maintenance, damage, improper repair, or alteration.
CUSTOMER SERVICE
In the event of equipment failure, call the Harris Products Group Customer Service
(800-240-0804). Please be prepared to provide the model number of the equipment
involved, in addition to some details regarding its application.
GENERAL SAFETY PRACTICES
Specific procedures for the safe use of this equipment are listed below.
1. Any relief devices protect only the regulator and are not intended to protect any
other equipment. Be sure that any downstream equipment is also protected by relief
device(s) if such equipment can not withstand full cylinder pressure.
2. Never use the regulator for gases other than labeled. It is designed to withstand
3000 PSIG maximum inlet pressure.
3. All connections to the regulator must be clean. Remove dirt or other foreign matter
from the regulator and external connections with a clean lint free cloth. Be sure to
use a new gasket for each installation when a gasket is used.
4. Never pressurize a regulator that has loose or damaged parts or is in questionable
condition. Never loosen a connection or attempt to remove a part until gas pressure
has been relieved. Under pressure, gas can dangerously propel a loose part.
5. Before transporting a cylinder that is not secured on a cart suitable for such
transport, remove the regulator and recap the cylinder.
6. Stand on one side of outlet of cylinder valve or regulator when opening valve.
Instruction Manual
Manuel d' Instruction
Manual de Instructiones
I MP OR TA NT
Pour votre propre sécurité,
lire ces instructions. Omettre
de les lire peut entraîner des
blessures graves.
7. Handle cylinder with care. Chain or otherwise secure cylinders to a permanent
fixture. Take care when moving. To transport cylinders (except when in cylinder
carts), remove regulators and replace with valve cap. Never use any cylinder in
other than an upright position.
8. Use "good housekeeping" in work areas. Keep sparks and flame away from
combustibles.
9.
Do not oil or grease equipment. The equipment does not require lubrication. Oil
or grease is easily ignited and burns violently in the presence of pure oxygen or
oxidizing gases.
10. "Crack" cylinder valve before installing regulator. Open valve slightly and then
close. This will clear valve of dust or dirt which may be carried downstream to the
regulator where it could cause damage or be a fire hazard. Do not discharge flow
of gas at any person or flammable material.
11. Be sure all connections are tight. Don't force connections. Never test for leaks with
a flame. Use a soapy water solution to check for leaks.
12. Use only recommended pressure settings. Improper pressures are wasteful.
Extreme pressure build up in regulators is a warning that they should be taken out
of service and repaired.
13. Do not work with damaged or leaking equipment. Use soapy water when checking
for leaks. Do not use frayed or damaged hose.
14. Handle equipment with care. Its continued good service and your safety depend
upon it.
15. Keep work area well ventilated. Flammable materials burn violently in an oxygen
atmosphere. Flames and glowing materials such as in tobacco smoking must be
avoided.
16. When working with acetylene, never use at pressures over 15 PSIG (Pounds Per
Square Inch Gauge).
17. DO NOT FORCE connectors and threads. The differences are intentional for the
various gases.
NOTE: SAVE THESE INSTRUCTIONS
INTRODUCTION
This manual provides installation, operation and service information for the model HP
705 series electrically heated, thermostatically controlled, multi-stage regulators. These
regulators have metal diaphragms which make them ideal for general laboratory uses

Publicidad

loading

Resumen de contenidos para Lincoln Electric HARRIS Multi-Stage 705 Serie

  • Página 1 Instruction Manual Manuel d’ Instruction Manual de Instructiones Heated Multi-Stage® Compressed Gas Regulators Régulateurs Multi-Étages® Chaffé, Pour Gaz Comprimé Reguladores De Calentamiento Eléctrico Multietapa, Para Gases Comprimidos IMPORTANT I MP OR TA NT For your own safety, read Pour votre propre sécurité, these instructions.
  • Página 2 as well as pressure control devices for critical analytical procedures. Generally, these Cet équipement et ses pièces ne doivent être modifiés en aucune circonstance. regulators are used for handling the gaseous withdrawal of Carbon Dioxide, Carbon L’utilisateur de cet équipement assume la responsabilité exclusive de tout défaut Dioxide Mixtures, and Nitrous Oxide.
  • Página 3 prendre en charge les retraits gazeux de dioxyde de carbone, mélanges de dioxyde de Partes dañadas, faltantes, desgastadas, deformadas o contaminadas son una indicación carbone et oxyde nitreux. de que el equipo no debe ser utilizado. Este equipo o cualquiera de sus partes nunca deben ser alteradas. El usuario de este Ces instructions sont réservées aux utilisateurs d’équipement générateur de gaz equipo será...
  • Página 4 Conecte la manguera del equipo siguiente en línea a la salida del regulador. Abra lentamente la válvula del cilindro. El regulador estará entonces listo para The Harris Products Group proporcionar presión al equipo siguiente en línea. A Lincoln Electric Company OPERACIÓN 2345 Murphy Blvd., Para Regular la Presión Gainesville, GA 30504-USA 1-800-241-0804 FAX: 770.535.0544...