OWNER'S MANUAL
14S and 16S Series
Little Giant 14S and 16S series submersible pumps are recommended for use in
basins or lift stations and suitable for sewage wastewater transfer, and dewa-
tering. These pumps have 2 inches (50.8 mm) spherical solids handling capa-
bility. For single phase models use with approved liquid level control with
correct rating that matches marked motor input in full load amperes or service
factor amperes. For three phase pumps use with approved motor control that
matches motor input in full load amperes with overload element(s) selected or
adjusted in accordance with control instructions.
This product is covered by a Limited Warranty for a period of 3 years from the
date of original purchase by the consumer. For complete warranty information,
refer to www.littlegiant.com.
Specifications
Discharge
Model
in (mm)
2 (51)
14S
3 (76.2)
16S
3 (76.2)
SAFETY INSTRUCTIONS
This equipment should be installed and serviced by technically qualified personnel who are familiar with
the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with
national and local electrical and plumbing codes and within Little Giant recommendations may result in
electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product's application, limitations, and potential hazards. Read and follow instructions carefully to
avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Refer to product data plate(s) for additional precautions, operating instructions, and specifications.
Failure to follow installation or operation procedures and all applicable codes may result in the following
hazards:
Risk of death, personal injury, or property damage due to explosion,
fire, or electric shock.
•
Do not use to pump flammable, combustible, or explosive fluids such as gasoline, fuel oil, kerosene, etc.
•
Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
•
Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
•
When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electrically disconnected.
•
If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of power.
•
If the disconnect panel is not accessible, contact the electric company to stop service.
HP
Volts
Hz
1/2
115
230
200-208
60
1
230
200-208
Amps
Watts
Phase
11.6
1100
1900
11
2000
1900
6.3
1500
6.8
800
EN
English
Shut Off
PSI
ft (m)
10.8
25 (7.6)
1
15.1
35 (10.7)
3