Net Weighing: Manual Tare Entry - Ravas 1100 Manual Del Usuario

Ocultar thumbs Ver también para 1100:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
 
A tare weight can be entered at any moment, meaning in either a loaded or unloaded situation. 
For a higher accuracy, a tare weight can be entered with a smaller graduation step, independent 
of the applied load and the active graduation of the indicator.  
 
A tare weight larger than the so‐called MAX1 of the weighing system will not be accepted by the 
indicator. The MAX1 is the value of the weight of the first range; in the standard version 200 kg 
(see 3.1.). If a larger weight is keyed in, the display shows: "HELP4". Upon pressing key PT, this 
HELP indication disappears.  
 
Press the PT key. 
  The display shows the current tare value. 
  The digit on the right flashes. 
  Press ENTER(
)  for three seconds if the current tare value is required. 
Or 
Press the PT key. 
Press the  key to go up a value or press the  key to go down a value until the required value 
is reached. 
  Press ENTER (
) to change the next value. 
  Repeat this procedure until the required tare value is displayed. 
 
To activate the tare weight, but without storage in the memory: press ENTER(
seconds. 
The tare weight is activated. 
  The "NET" pointer lights up. 
When the system is loaded at this moment, the net value appears in the display. 
When the system is unloaded, the read‐out displays the given tare value negatively . 
The keyed in value remains active until the system is turned off, a new tare weight is 
entered, a new load is tared (see 3.4.) or by resetting the tare value to zero: 
The weighing system is loaded: press the PT key for two seconds. The tare value is set 
to zero and the system returns to the standard weighing mode.  
Or 
The weighing system is unloaded: press the 
the system returns to the standard weighing mode. 
 
To activate the tare weight and store it in memory: go through all the digits by pressing 
ENTER(
).  
The tare weight is activated and stored in the memory. 
  The  "NET" pointer lights up. 
When the system is loaded at this moment, the net value appears in the display. 
When the system is not loaded, the tare value input is displayed negatively. 
The keyed in value remains active, even if the system is turned off, until a new tare weight 
is entered, a new load is tared (see 3.4.) or by resetting the tare value to zero: 
0/T
 key. The tare value is set to zero and 
‐ 10 ‐ 
) for three 

Publicidad

Tabla de contenido
loading

Tabla de contenido