3. REMOTE CONTROL
The AURORA NET software allows you to manage in real time several parameters of the VIO S115 subwoofer.
In particular:
•
Monitor the input and output signals
•
View the presence of audio compression on the acoustic component
•
Attenuate the input signal in steps of 0.5 dB
•
Add delay in steps of 0.1 ms
•
Activate cardioid mode (with settings of two or three elements)
•
In Link mode, select the cut-off frequency to be applied to the low-pass filter with preset
values ranging from 70 to 120 Hz
•
In XOVER OUT mode, select the cut-off frequency to be applied to the output signal with
preset values ranging from 70 to 120 Hz
•
Reverse the phase of the subwoofer
•
MUTE the subwoofer
•
Listen to the subwoofer in SOLO mode.
•
Monitor the temperature of the amplifie
•
Calibrate the tilt angle of the subwoofer
•
Save settings as presets for subsequent remote recall