6. UPDATING THE FIRMWARE
It is very important to keep the product firmware updated to ensure full functionality. Periodically check the
"DOWNLOADS" section of the http://www.dbtechnologies.com website.
1. Download and install the USB BURNER MANAGER onto your computer from the
CONTROLLER" section.
2. Download the .zip file of the latest firmware for your product from the "DOWNLOADS" section.
3. Connect the product to the PC using a USB cable (not supplied) with the correct connector type (see this
detail in the AMPLIFIER AND CONTROL SECTION FEATURES chapter).
4. Select "Open File" at the top right of the USB BURNER MANAGER screen.
5. Select the previously downloaded firmware file.
6. Follow the instructions shown on the screen.
7. Click "UPDATE".
7. TECHNICAL SPECIFICATIONS
GENERAL
Type:
ACOUSTIC DATA
Frequency response [-6 dB]:
Frequency response [-10 dB]:
Max SPL (@ 1m):
LF:
LF Voice Coil:
Crossover frequency:
AMPLIFIER
Type:
Amplification class:
Peak power:
RMS power:
Power supply:
Cooling method:
VIO S115
38
"SOFTWARE &
Active bass reflex subwoofer
40 Hz - cut-off frequency (depends on Xover)
36 Hz - cut-off frequency (depends on Xover)
134 dB
15"
4"
Selectable from 70 Hz to 120 Hz
Digipro® G3
Class D
1800 W
900 W
Auto-range
Passive convection
English
Cod. 420120357 REV. 1.0