9 Quick commissioning

Quick commissioning only covers basic and motor-specific settings. User-specific settings must be entered
in accordance with the manufacturer's documentation.
See: Parameters list, user documentation: Siemens document number: 6SE6400-5BA00-0AP0
Operation of the device is described in the following manufacturer's documentation:
Micromaster 420 operating instructions: Siemens document number: 6SE6400-5AA00-0AP0
Parameter
Value range/setting
number
P0003
Access level
0: User-defined parameters list
1: Standard, access to the most frequently used parameters
2: Extended, extended access, e.g. to converter I/O functions
P0010
Commissioning parameter
0: Ready
1: Quick commissioning
P0100
Europe/North America
0: Europe [kW], standard frequency of 50 Hz
P0300
Motor type selection
1: Asynchronous motor
P0304
Nominal motor voltage
P0305
Nominal motor current
P0307
Nominal motor power
P0700
Command source selection
2: Terminal strip
P1000
Frequency setpoint selection
2: Analogue setpoint
P1080
Min. speed
0 ... 5.00 Hz ... 650 Hz
P1082
Max. speed
0 ... 150.00 Hz ... 650 Hz
24
Three-phase
Three-phase
asynchronous motor
asynchronous motor
Order no. 571874
Order no. 571874
Star mode
Delta mode
400 V
230 V
0.76 A
1.32 A
0.25 kW
0.25 kW
MPS transfer line
MPS transfer line
MT AC
MT AC
Order no. C93102
Order no. C93102
Star mode
Delta mode
400 V
230 V
0.1 A
0.17 A
0.022 kW
0.026 kW