GB
every time when there is a break in work.
Pulling and holding the trigger in this position and then turning the lock in the opposite direction to closckwise will lock the trigger in
the pulled-in position. The lock can be used during long-lasting spraying of the coating material. Unlocking the trigger takes place
by lightly pressing and holding the trigger in this position, and then turning the knob in the clockwise direction.
Spray nozzle knob (VII). The knob allows disassembly of the nozzle for easy maintenance. The knob has been marked with an
arrow. Turning the knob so that the arrow points towards the outlet of the gun allows you to spray the coating material.
Turning the knob so that the arrow points towards the pistol grip allows you to clean the nozzle, and also allows you to disassemble
the nozzle.
In addition to cleaning, make sure that the nozzle is positioned to spray the coating material.
Electric switch (VIII). The switch allows to enables and disables the unit. Turning the switch to the position marked "I - switched
on" will start the unit. Turning the switch to the position marked "O - off " will immediately switch off the unit. During operation, the
unit should be set in such a way that the switch is always easily accessible.
Connecting the unit to the mains
Caution! The unit must always be connected to a socket with an earthing wire.
Caution! The connection installation should be equipped with a residual current device with a tripping current of no more than 30 mA.
Before connecting the unit to the mains, make sure that the switch is in the "O - off " position. The trigger gun remains blocked from
accidentally pressing. The pressure control knob has been set to the lowest pressure setting.
Connect the unit by inserting the plug of the power cable by inserting it into a power socket.
If you use extension cords to deliver a power to the product, make sure that the cross-section of the extension cable wires is not
smaller than the cross-section of the product's power cord wires. The cross section of the power cable wires has been marked
on the power cable insulation. Only power cables equipped with an additional protective conductor may be used. Do not use
two-core extension cables.
In case of using the extension cables with a length of more than 10 m, the conductor cross section should not be less than
mm2.
2.5
Do not use the extension cables longer than 50 m.
In case of using a retractable extension cables, they must be fully unwound before connecting.
Filling the product with a coating material
Prepare the container and fi ll it with clean water or a thinner recommended by the coating material manufacturer.
Prepare an empty container with the same or greater capacity as the container with the thinner.
Prepare an empty container for the coating material spray test.
Prepare a container fi lled with coating material.
Loosen the overfl ow hose (smaller diameter) from the suction hose hooks.
The outlet of the overfl ow hose should be directed to an empty tank, fastened so that it does not slip out automatically.
Insert the suction hose into a container fi lled with water or a thinner. The mesh fi lter must always be under the surface of the
thinner.
Make sure that the gun nozzle is in the operating position and the trigger is locked against accidental pressing.
Turn the operating mode selector switch to the position intended for fi lling the product.
Set the pressure control knob in such a position that the indicator shows the range for cleaning or fi lling the product installation.
Plug the power cord into a power outlet, and then turn the unit on using the switch.
The unit will start sucking the thinner. The thinner and the air bubbles will emerge form the overfl ow hose. Wait for 30 to 60 sec-
onds, make sure that only the thinner emerges from the overfl ow hose, and then turn off the unit with the switch.
Carefully insert the suction hose into the container with the coating material. The mesh fi lter must always be under the surface of
the thinner. While handling the hose, try to avoid splashing the thinner, in particular on the unit or electrical installation. In the case
of splashing, dry the residual thinner before starting the unit.
Start the unit with the switch.
The unit will start sucking the coating material. A thinner mixed with the coating material will emerge from the overfl ow hose. Allow
only the coating material to emerge from the overfl ow hose.
Direct the gun nozzle to the empty container, set the operating mode selector to the position that allows spraying coating material.
Unlock the trigger and press it, wait for the coating material to emerge from the gun nozzle. Release the pressure on the trigger
and lock it in this position.
Take the drain hose out from the container and attach it to the suction hose hooks so that the ends of both hoses are under the
surface of the coating material.
If the motor of the unit stops, it means that the pump and hoses have been properly fi lled with the coating material.
Otherwise, repeat the entire process from the beginning.
Corectly fi lled product is ready to spraying the coating material. Work should be started immediately after fi lling the product.