Basic settings
White Balance. In this parameter, you can adjust the color temperature. The default option is "Auto White Balance".
Exposure. In "Auto Exposure", you can set the exposure value. In "Manual Exposure", you can adjust the "time" parameter.
Color Adjustment. In this parameter, you can adjust saturation, hue, brightness, and contrast.
Monochrome. By selecting this parameter, you will see the image in different tones of a single color (e.g. shades of gray).
Flip. This feature allows you to flip the image horizontally or vertically.
Measurements
1.
Cross Line. You can select a cross line in four colors, turn the display on or off, and adjust the position of the center point of
the cross line.
2.
Calibration. The camera is calibrated by default, but you may need to recalibrate the camera.
• Put the calibration slide on the stage so that the scale is placed horizontally on the screen. Adjust the focus as clearly as
possible.
• Enter the Calibration menu. Drag a segment of the calibration ruler so that its ends are next to the marks on the physical
scale of the calibration slide. For maximum accuracy, try to capture as many scales as possible.
• Example: The image above uses a ruler with 0.01mm (10µm) divisions under a 10x lens. The camera parameters are set
to: "magnification 10x", "units μm", and "length 40".
• Each objective lens must be calibrated to take measurements at different magnifications.
• After adjusting the parameters, exit the calibration menu to complete the procedure.
3.
Recalibration. The calibration process has to be repeated if the magnification or focus has been changed during
observations. Enter the Measurement menu. Select the magnification, adjust the start and end point, and then the value of
the measured segment will be displayed.
Fuse replacement (Levenhuk D95L LCD)
Unplug the microscope from a power source. Open the fuse holder located on the back of the microscope body with a flat head
screwdriver. Remove the old fuse and install a new one. Only use the appropriate types of fuses. Close the fuse holder.
Specifications
Product ID
Model
Type
Research method
Magnification
Eyepiece head
Optics material
Objectives
Revolving nosepiece
Stage moving range
Stage
Focus system
Condenser
Body
Illumination
Collector
Filters
Vial of immersion oil
Fuse
Power supply
78902
Levenhuk D85L LCD
60x, 150x, 600x
achromatic: 4x, 10x, 40x
3 objectives
90x90mm, with specimen holders
coaxial, coarse (15mm) and fine (0.002mm)
N.A. 0.65 with diaphragm disk
(6 apertures)
upper and lower (0.2W LED) with
brightness adjustment
+
3pcs AA batteries or 110—220V, via AC
adapter
8
Levenhuk D95L LCD
biological/optical, digital
bright field
60x, 150x, 600x,1500x
7" color LCD screen
optical glass
achromatic: 4x, 10x, 40xs, 100xs (oil)
double layer mechanical, 110x126mm,
with mechanical scale
Abbe N.A. 1.25 iris diaphragm and filter
metal
lower (1W LED) with brightness
110—220V, via AC adapter
78903
4 objectives
70/30mm
holder
adjustment
+