Configuration
Setting the identification code
In the front door unit, each 4 push-button module is recognised by
its identification code (from 0 to 7).
ON
The code is set using the rear DIP switch, as shown in the fol-
lowing table.
ATTENTION: before changing the position of any switch,
make sure that the module is not powered.
Code
DIP 1
DIP 2
DIP 3
0
OFF
OFF
OFF
1
OFF
OFF
ON
2
OFF
ON
OFF
3
OFF
ON
ON
Modules with the same identification code may not co-exist in the
same front door unit (the same identification code may be used in
other front door unit).
Logical connection between the push-buttons of the 4 push-
button module and the apartment units
Refer to the instruction sheet for the main modules for the con-
nection between the push-buttons of the 4 push-button module
and the apartment units.
Completion
Closing the frame
When configuration is complete, close the front door unit, fixing
the frame to its box.
Cover plate
1
2
1
2
3
Code
DIP 1
4
ON
5
ON
6
ON
7
ON
Hook the cover plate to the module
holder frame and fix it with the clo-
sing screws, using a spanner or Torx
screwdriver (T20).
open
close
Inserting the name labels
To insert, or replace, the name label associated with a call push-
button, proceed as follows:
1.
Open the transparent name
holder label using a small
screwdriver with a flat tip.
2.
Insert the name label on the
back of the transparent label.
Empty name holder labels are
provided; if you want to print
your own labels, the size
must be 64 x 15 mm.
DIP 2
DIP 3
3.
Press the transparent name holder label to close it.
OFF
OFF
OFF
ON
Cleaning the module
ON
OFF
ON
ON
Use a dry cloth to clean the 4 push-button module if necessary.
Pack Contents
1 Module with 4 push-buttons for front door unit
1 Fitted multi-pole connection cable - 0.25 m
4 Name holder labels
2 Frame fixing screws
1 Instruction sheet

Technical data

Power supply
Current consumption
Control elements
Display elements
Configuration elements
Lighting elements
Connection to other modules for front
door unit
Usage environment
Operating temperature
®
Storage temperature
Relative humidity
Weight
Degree of protection
Dimensions (L x H x D)
Reference standards
Via the audio or audio/video module
70 mA max.
4 call buttons
4 red LEDs for signalling the call status
1 - 3 pin DIP switch
4 LEDs for name holder label rear
illumination
2 - 8-pin polarised through-connectors
Outdoor/indoor, protected from the rain
and water infiltrations
-15 ÷ +50 °C
-15 ÷ +70 °C
Max. 93% (non condensative)
0.13 kg
IP44
115 x 85 x 43.5 mm
Electromagnetic compatibility:
2004/108/EC, EN 61000-6-1, EN 61000-6-3

Publicidad