Polaris
AutoClear
SC Salt Chlorinator
®
TM
3.5 Cell and Flow Switch Assembly
Instructions
Cell Adapter Assembly
Wrap with
Teflon tape
Outlet
Flow Switch Assembly
Outlet
Figure 6.
Assembling the Cell
Figure 7.
Disassemble the Cell
Figure 8.
Water Flow
|
Installation and Operation Manual
Inlet
Wrap with
Teflon tape
Inlet
ENGLISH
Align the bump
with the high
thread on the
lower clamp.
Figure 9.
Locking Ring Alignment
1. Screw down the locking ring to the threaded clamp
using the locking ring tool.
Figure 10.
Locking Ring Tool
NOTE: Ensure the locking ring is level when engaging the
threading housing.
Figure 11.
Locking Ring Level
2. Install the flow switch making sure the arrow on
the flow switch points in the direction of the water
flow. Make sure the switch is in line with the pipe.
3. Securely connect the cell leads to the like colored
terminals.
4. Attach the terminal cap.
Page 11
NOTE: The
Upper Clamp
is not shown
in this diagram
but it should be
installed.