Installation
WARNING! Do not connect the appliance to the mains until the installation is fully complete.
Fitting the extractor hood
To the wall
With 3 screws.
1. Mark mounting boreholes.
Dimensions can be found in or use
template.
2. Drill 8 mm dia. holes and insert wall plugs
flush with the wall.
3. Screw in the upper screws (on left and
right) until there is a gap of approx.
7 mm between the screw head and the
wall.
4. Remove the filter grille (see Instructions
for use)
5. Attach the extractor hood.
6. Tighten the lower screw (with washer)
inside the extractor hood.
12
7 mm
Fitting the extractor hood
To a wall-hanging cupboard
With 4 screws.
1. Dimensions for the mounting boreholes
can be found in, or place a template on
the base of the wallhanging cupboard.
2. Mark the mounting holes and make pilot
holes with a bradawl.
In exhaust-air mode (upwards) mark the
exhaust-air opening and saw out.
❑ Consider the location of the
connection cable; if required, saw out the
cupboard.
3. Remove the filter grille (see Instructions
for use).
4. Screw the extractor hood to the base of
the cupboard.