Ensure that you do not damage the depth-measuring blade
¡
¡
6 or the object you want to measure by exerting too much
pressure on them.
The LCD display 5 now displays the dimensions.
¡
¡

After measurement:

After carrying out the measurement, move the external
¡
¡
measuring jaws 11 / internal measuring jaws 2 together
again by turning the handwheel 7 inwards clockwise.
Switch the LCD display 5 off again by pressing the
¡
¡
ON / OFF key 10.
Tip: The LCD display 5 automatically switches itself off
after approx. 5 minutes.
Tighten the locking screw 4 again by turning it clockwise
¡
¡
until you feel some resistance.
˜ Examples of use
Tip: When measuring, always proceed as described in the
chapter on using the calliper.
Comparison of plug and socket (see Fig. C):
First measure the dimensions of the plug (see Fig. C.1).
¡
¡
You may wish to make a note of the measurement.
¡
¡
Then measure the socket (see Fig. C.2).
¡
¡
Deviation from a reference value (see Fig. D):
Measure a reference object (in this case A) (see Fig. D.1).
¡
¡
Leave the measuring jaws 2 / 11 in this position and press
¡
¡
the key to obtain the zero setting (ZERO) 9 .
Then measure the second object (see Fig. D.2). The LCD
¡
¡
display 5 now shows the deviation of the measurement of
the second object to that of the reference object (A).
Measuring the thickness of the floor of an object
(see Fig. E):
First measure the depth of the object (see Fig. E.1).
¡
¡
Leave the depth blade 6 in this position and press the key
¡
¡
to obtain the zero position (ZERO) 9 .
Now measure the entire object (see Fig. E.2). The LCD
¡
¡
display 5 now shows the thickness of the floor of the
object.
Measuring the distance between two identical
holes (see Fig. F):
First measure one of the two, equally sized holes
¡
¡
(see Fig. F.1).
Leave the measuring jaws 2 / 11 in this position and press
¡
¡
the key to obtain the zero position (ZERO) 9 .
Now measure the total dimension (see Fig. F.2). The LCD
¡
¡
display 5 now shows the average distance.