5.3.2 USER PARAMETER
Press the key Prg and enter on MAIN MENU
- - -Main Menu - - -
START/STOP
USER SETTINGS
SERVICE
INFORMATION
Select USER SETTINGS, press Enter to confi rm.
Shows the "user setting menu":
- User Settings Menu -
DRYER SETTINGS
DATE/TIME
BMS
MOISTURE DRAIN
OTHER
LANGUAGE
Select DRYER SETTINGS press Enter to confi rm. This Screen appears
U1 - DEWP.SET (°C):
U2 - PRESSURE (barg):
U3 - MODE: Forced Rig.
U4 - ALARM RELAY MODE:
by: ALARMS & WARNINGS
U6 - DPM:
NO FITTED
With the keys Up,Down and Enter you can select/change a parameter:
U1 - SET of Dew Point
U2 -Work pressure [barg]
U3 - Working Mode: Forced Rig. O Normal
U4 - Alarm Relay Mode by: alarms&warnings or allarms.
U6 - DPM: Fitted o No Fitted - with the control fo the dew point (Fitted)
or with fi xed time (No Fitted)
When you change the parameter press Enter to confi rm.
Press Esc to return on USER SETTINGS MENU.
Select DATE for change the date and the time:
- User Settings Menu -
DRYER SETTINGS
DATE/TIME
BMS
MOISTURE DRAIN
OTHER
LANGUAGE
This Screen appears:
2011/Oct/24
15.49
Change: NO
Press esc to return on USER SETTINGS MENU.
Select BMS:
- User Settings Menu -
DRYER SETTINGS
DATE/TIME
BMS
MOISTURE DRAIN
OTHER
LANGUAGE
This Screen appears:
English
The parameters U7 and U8 selects the adress fo the supervision.
Press esc to return on the USER SETTINGS MENU.
Select MOISTURE DRAIN:
This Screen appears:
-40
07
U9 - Mode condensate drain (continue; timed; capacitive);
U10 - Time "ON" with timed condensate drain;
U11 - Time "OFF" with timed condensate drain;
Press Esc to return on USER SETTINGS MENU.
Select OTHER:
This Screen appears:
5.3.3 SERVICE PARAMETER
On MAIN MENU select Service and press Enter to confi rm.
M10
This Screen appears with the request of a password.
- BMS -
U7 - ADRESS:
001
U8 - BAUDRATE:
9600
- User Settings Menu -
DRYER SETTINGS
DATE/TIME
BMS
MOISTURE DRAIN
OTHER
LANGUAGE
- MOISTURE DRAIN -
U9 - MODE: Continue
U10 - TIMED
On (s):
U11 - TIMED
Off (s):
1
- User Settings Menu -
DRYER SETTINGS
DATE/TIME
BMS
MOISTURE DRAIN
OTHER
LANGUAGE
U12 - BACKLIGHT ON:
NO
U13 - Enable Money
:
NO
U14 - Money : Euro
U15 - Money / KWh
:
0.120
U16 - Saving Compared
to Heatless
U2
- - -Main Menu - - -
START/STOP
USER SETTINGS
SERVICE
INFORMATION
ATT025-040
INSERT PASSWORD
000
These confi guration parameters must not be editable by the customer.
5.3.4 INFORMATIONS
On MAIN MENU select INFORMATION and press Enter to confi rm.
- - -Main Menu - - -
START/STOP
USER SETTINGS
SERVICE
INFORMATION
From this page you can view system information and alarm history.
Select SYSTEM INFOand press Enter to confi rm:
- - - Informations Menu - - -
SYSTEM INFO
ALARMS HISTORICAL
Using Up and Down. You can view:
-
Information on cycles times;
-
Values input signals:
INPUTS
Pressure 1 (B6) :
Pressure 1 (B7) :
Level (B8) :
AD Inlet Temp (B9):
Thermal Mass (B10):
-
Counter
2014/Gen/24 16.20.20
HOURS COUNTERS
UNIT_ON :
000001
COMPRESSOR :
000001
LAST OFF DAY :
00,00.00
-
Information about software
SOFTWARE INFO
SW Release :
SW date:
2014/01/20
Bios :
5.00. 20/May/01
Boot :
4.00. 20/May/01
'
04.2
04.3
NO WAT:
02.6
02.4
(h)
(h)
S1
10
5 / 12