INSTALLATION
Selection of installation equipment
Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 50mm space shall be preserved around the hole.
Be sure the thickness of the work surface is at least 30mm. Please select heat-resistant work surface
material to avoid larger deformation caused by the heat radiation from the hotplate. As shown below:
L(mm)
W(mm) H(mm)
590
520
50
Under any circumstances, make sure the ceramic cooker hob is well ventilated and the air inlet and
outlet are not blocked. Ensure the ceramic cooker hob is in good work state. As shown below
Note: The safety distance between the hotplate and the cupboard above the hotplate should be
at least 760mm.
A(mm)
B(mm)
760
50 mini
D(mm)
A(mm) B(mm)
46
562
C(mm)
D
20 mini
Air intake
X(mm)
492
50mini
E
Air exit 5mm