Operating Temperature - HTW ADMIRA -D-035ADMR32 Manual De Usuario E Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Display panel
Manual
button
MANUAL button : This button selects the mode in the following order: AUTO, FORCED COOL, OFF.
FORCED COOL mode : In FORCED COOL mode, the Operation light flashes. The system will then
turn to AUTO after it has cooled with a high wind speed for 30 minutes. The remote control will be
disabled during this operation.
OFF mode : When the display panel is turned OFF, the unit turns o and the remote control is
re-enabled.

Operating temperature

When your air conditioner is used outside of the following temperature ranges, certain safety
protection features may activate and cause the unit to disable.
Inverter Split Type
Room Temperature
Outdoor
Temperature
(32 ° F - 126 ° F)
(For special
tropical models)
Timer
indicator
Operation
indicator
PRE-DEF
(pre-heating/defrost)
indicator
COOL mode
HEAT mode
17°C - 32°C
0°C - 30°C
(62 ° F - 90 ° F)
(32 ° F - 86 ° F)
0°C - 50°C
(32 ° F - 122 ° F)
-15°C - 50°C
-15°C - 24°C
(5 ° F - 122 ° F)
(For models with
low temp.
cooling systems.)
0°C - 52°C
Infrared
receiver
Alarm
indicator
DRY mode
10°C - 32°C
(50 ° F - 90 ° F)
0°C - 50°C
(32 ° F - 122 ° F)
0°C - 52°C
(32 ° F - 126 ° F)
(For special
tropical models)
LED display
FOR OUTDOOR UNITS
WITH AUXILIARY
ELECTRIC HEATER
When outside
temperature is below 0°C
(32 ° F), we strongly
recommend keeping the
unit plugged in at all time
to ensure smooth
ongoing performance.