Temperature setting of freezing chamber
Click the button
of temperature
adjusting button of the freezing chamber, the set temperature will be reduced 1 °C;
The temperature setting range for freezing chamber is -24~ -16°C. When the temperature is -24 °C,
click the button again, the set temperature of freezing chamber will switch to -16 °C.
Mode setting
Quick cool mode
Long press the button
T he refrigerating chamber temperature display 2℃, enter the Quick cool mode.
Under Quick cool mode, long press the button
exit
Quick cool mode. The set temperature of refrigerating chamber will automatically switch back
t
o set temperature before
Quick freeze mode
Long press the button
T h e freezing chamber temperature display - 24℃, enter the Quick freeze mode.
Under Quick freeze mode, long press the button
exit Quick freeze mode. The set temperature of freezing chamber will automatically switch back to
set temperature before Quick freeze mode. When set vacation mode,exit Quick freeze mode.
Vacation mode
click the button
Th e refrigerating chamber temperature display go out,the freezing chamber temperature display - 18℃
enter the vacation mode.
Under vacation mode, click the button
The set temperature of refrigerating chamber and freezing chamber will automatically switch back to set
temperature before vacation mode.
When set Quick cool mode and Quick freeze mode ,exit vacation mode.
Opening warning and alarm control
When open the refrigerator door, the door open music will play. If the door is not closed in two minutes,
the buzzer will sound once every minute until the door is closed. Press any one button to stop the
buzzer alarm.
Fault indication
The following warnings appearing on the display indicate corresponding faults of the refrigerator.
Though the refrigerator may still have cold storage function with the following faults, the user shall contact
a maintenance specialist for maintenance, so as to ensure optimized operation of the appliance.
to change the set temperature of freezing chamber ,
for 3s
Quick cool mode.When set vacation mode,exit Quick cool mode.
for 3s
to set vacation mode,The icon
Fault Description
Fault Code
Temperature sensor failure
E1
of refrigerating chamber
Temperature sensor failure
E2
of freezing chamber
Temperature sensor failure
E3
of chill drawer
Freezing defrost
E5
circuit error
E6
Communication error
Ambient temperature sensor error
E7
to set Quick cool mode, The icon
for 3s
to set Quick freeze mode,The icon
for 3s
lights up.
again,The icon
sensor
detection
13
each click
lights up.
,The icon
go out .
lights up.
,The icon
go out .
go out .exit vacation mode.