WARNING
To reduce the risk of fire, use only metal ductwork.
1. Decide where the ductwork will run between the
hood and the outside.
2. A straight, short duct run will allow the hood to
perform most efficiently.
3. Long duct runs, elbows and transitions will reduce
the performance of the hood. Use as few of them
as possible. Larger ducting may be required for best
performance with longer duct runs.
4. Install a wall cap or roof cap. Connect round metal
ductwork to cap and work back towards the hood
location. Use duct tape to seal the joints between
ductwork sections.
The minimum hood distance above cooktop MUST NOT
BE LESS than 24".
A maximum of 30" above cooktop is highly recom-
mended for best capture of cooking impurities.
Distances over 30" are at the installer and users discre-
tion; providing that the ceiling height permits.
1. Construct wood wall framing that is flush with
interior surface of wall studs.
Make sure:
a) the framing is centered over installation
location.
b) the height of the framing will allow the
mounting bracket to be secured to the framing within
the dimensions shown.
2. After wall surface is finished, carefully center and
level the hood mounting bracket and secure it to
wall framing with (3) #8 x 1-1/2" mounting screws.
Tighten the screws completely.
Note: Do not use drywall anchors.
CEILING
DUCT
HEIGHT
METHOD
DUCTED OR
8 FEET
36-3/4"
NONDUCTED
9 FEET
DUCTED OR
36-3/4" * 37-3/4" * 38-3/4" * 39-3/4" * 40-3/4" * 41-3/4" * 42-3/4" *
NONDUCTED
* WITH OPTIONAL FLUE EXTENSION - PART NUMBER 59920.
All manuals and user guides at all-guides.com
INSTALL THE DUCTWORK
INSTALL MOUNTING BRACKET
HOOD DISTANCE ABOVE 36" COOK TOP (SEE NOTE 1)
24"
25"
26"
27"
MOUNTING BRACKET LOCATION ABOVE 36" HIGH COOK TOP
37-3/4"
38-3/4"
39-3/4"
6"
ROUND DUCT
DECORATIVE
FLUE
24"
COOKING SURFACE
36¾" = bottom of hood 24" above cooktop
42¾" = bottom of hood 30" above cooktop
MOUNTING BRACKET LOCATION
(ABOVE 36" HIGH COOKTOP)
28"
29"
30"
40-3/4"
41-3/4"
42-3/4"
6
ROOF CAP
ROUND ELBOW
HOOD MOUNTING
3 /4
12-
OF HOOD MOUNTING
HOOD
BRACKET HOLES
3-
DUCT
30"
TO
ABOVE
CENTER
LINE
WALL STUDS
FRAMING BEHIND
DRYWALL
L
C
9"
4
⁄
"
1
2
NOTES:
Minimum hood distance above cooktop must
not be less than 24".
A maximum of 30" above the cooktop is
highly recommended for best capture of
cooking impurities.
Distances over 30" above the cooktop are
at the installer's and user's discretion -
providing that ceiling height and flue length
permit.
WALL CAP
BRACKET
"
TO CENTER
3 /8
"
1
⁄
"
9
1 6