Install Upper Flue Mounting Bracket; Prepare The Hood - Kenmore 233.5992 Serie Manual De Uso Y Cuidado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. If a framing member is not present, drill two
5 ⁄ 1 6" diameter holes where shown. Insert dry-
wall anchors into the holes.
2. Center the bracket over the hood location and
flush with the ceiling. Make sure that the slots
of the upper flue bracket are at the bottom.
Secure the upper flue bracket to the wall using (2)
#8 x 1½" mounting screws.
3. Tighten the screws completely. Make sure that
the bracket is tight against the wall.
1. GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event
of an electrical short circuit, grounding reduces
the risk of electric shock by providing an escape
wire for the electric current. This appliance
is equipped with a cord having a grounding
wire with a grounding plug. The plug must be
plugged into an outlet that is properly installed
and grounded.
2. Position the electrical outlet within the space
covered by the decorative flue and where it
will not interfere with the round duct. Make sure
the outlet does not interfere with the mounting
bracket fastening area, ductwork, or where the
decorative flue touches the wall.
All manuals and user guides at all-guides.com

INSTALL UPPER FLUE MOUNTING BRACKET

INSTALL THE WIRING
Center of installation
Recommended
distance
between
screw
holes
2
7
"
8
Center of
Ceiling
installation
Upper flue mounting
bracket slots
LOCATE
ELECTRICAL
OUTLET
WITHIN
THESE
AREAS.
(Verify
location
will not
interfere
with duct,
mounting
brackets,
and flue.)
7
Ceiling
L
C
1
1
"
8
5¾"
Ø 5/16"
TYP.
Flush with
the ceiling
C
L
10"
BACK OF
HOOD
4"
20-3/4"
13"

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

233.5993 serie

Tabla de contenido