3.5
Lithium­ion battery status display
The charge state of the Li-ion battery and malfunctions of the product are indicated by the indicator of the
Li­ion battery. The state of charge of the Li­ion battery is displayed after pressing one of the two battery
release buttons.
Status
4 LEDs light.
3 LEDs light.
2 LEDs light.
1 LED lights.
1 LED flashes.
Battery state of charge cannot be displayed while the control switch is pressed and for up to 5 seconds
after releasing the control switch. If the LEDs of the charge state indicator flash, follow the instructions
in the 'Troubleshooting' section.
3.6
Items supplied
Crimping / pressing tool, operating instructions.
Other system products approved for use with this product can be found at your local Hilti Store or at:
www.hilti.group
3.7
Selecting the crimping / pressing die
A table to assist with selecting the type of crimping / pressing die to be used can be found at the end of
these operating instructions.
4

Technical data

Rated voltage
Weight in accordance with EPTA Procedure 01 including B22⁄8.0
battery
Crimping / pressing time
Max. crimping / pressing force
Max. permissible crimping capacity
Storage temperature
Ambient temperature for operation
4.1
Noise information and vibration values in accordance with EN 60745
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure. The data given represents the main applications of the power tool.
However, if the power tool is used for different applications, with different accessory tools, or is poorly
maintained, the data can vary. This can significantly increase exposure over the total working period. An
accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the
total working period. Identify additional safety measures to protect the operator from the effects of noise
and/or vibration, for example: Maintaining the power tool and accessory tools, keeping the hands warm,
organization of work patterns.
Noise values
Sound power level (L
WA
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
*2215654*
)
)
WA
)
pA
)
pA
2215654
Meaning
State of charge: 75 % to 100 %
State of charge: 50 % to 75 %
State of charge: 25 % to 50 %
State of charge: 10 % to 25 %
State of charge: < 10 %
21.6 V
7.5 kg
8 s ... 9 s
120 kN
750 MCM (400 mm²) Cu
750 MCM (300 mm²) Al
−20 ℃ ... 70 ℃
−17 ℃ ... 60 ℃
80 dB(A)
2.5 dB(A)
70 dB(A)
2.5 dB(A)