Gas Connection Requirements - KitchenAid 720-0787 Instrucciones De Instalación Y Manual De Uso Y Cuidado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Burner Requirements for High Altitude
Input ratings shown on the model/serial rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at a
rate of 4% for each 1,000 ft (304.8 m) above sea level. Orifice
conversion is required. See "Assistance" section to order.
Gas Supply Line Pressure Testing
Testing above 1/2 psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge):
The grill and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of
that system at test pressures greater than 1/2 psi (3.5 kPa).
Testing below 1/2 psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge)
or lower:
The grill must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to
or less than 1/2 psi (3.5 kPa).

Gas Connection Requirements

20 lb LP Gas Fuel Tank
This grill is equipped for use with a 20 lb LP gas fuel tank (fuel
tank not supplied). A gas pressure regulator/hose assembly is
supplied.
Any brand of 20 lb LP gas fuel tank is acceptable for use with the
grill, provided that it is compatible with the grill's retention means
(tank tray included).
(tank tray included).
It is also design-certified by CSA International for local LP gas
supply or for Natural gas with appropriate conversion.
A. Gas pressure regulator/hose assembly
The 20 lb LP gas fuel tank must be mounted and secured.
Tank hole
1. Open cabinet door.
2. Twist the tank bolt counterclockwise until it is loosened.
All manuals and user guides at all-guides.com
A
A. Tank bolt
3. Place the 20 lb LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
4. Tighten the tank bolt clockwise against the bottom collar of the
20 lb LP gas fuel tank to secure.
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The
qualified Natural gas technician shall provide the Natural gas
supply to the selected grill location in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest
edition, and local codes. For conversion to Natural gas, the
Natural Gas Conversion Kit supplied with the grill (on some
Natural Gas Conversion Kit supplied with the grill (on some
models) or the Natural Gas Conversion Kit Part Number
W10118098 must be used. See "Assistance" section for
information on ordering.
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
Follow instructions for converting to Natural gas in the "Gas
Conversions" section of this manual or the instructions
supplied with Natural Gas Conversion Kit Part Number 710-
0003.The gas supply line shall be equipped with an
approved shutoff valve. This valve should be located in the
same area as the grill and should be in a location that allows
ease of opening and closing. Do not block access to the
shutoff valve. The valve is for turning on or shutting off gas to
the grill.
A. Gas supply line
B. Shutoff valve "open" position
C. To grill
A
7

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

730-0787

Tabla de contenido