ƒ Never run or jump whilst attached to the unit, walking
at a steady pace will ensure that the device does not
sense a fall.
ƒ As there may be a risk of injury during fall arrest due
to a collision with parts of buildings or constructions
the relevant risk assessments must be carried out and
measures taken to eliminate or reduce the possibility
of injury.
ƒ Ensure the lifeline is free to extend and retract from the
device, and that the brake engages with a sharp jerk,
before use. The line between the user and the device
must be taught at all times.
ƒ For W2TH Dual Kits, assemble and use RTFA
according to instruction sheet provided with Dual
RTFA Bracket.
ƒ The deflection of the anchor device shall be taken into
account when determining the clearance required
below the feet of the user.
ƒ If using RTFA with scaffold hook, RTFA housing must
always be attached at harness dorsal D-ring. Scaffold
hook must ONLY be connected to structural rebar, or
other structural anchor (such as angle iron or concrete
form) deemed compatible by a Competent Person.
ƒ During horizontal use, the working area or lateral
movements to both sides of the centre axis of device
anchorage point must be limited to a maximum of
1.5m.
See diagram C, page 14.
ƒ C10HW & C15HW only!
Ensure the FMS cover is not damaged and does NOT
show any signs of deployment before use. See page
16 for further details on inspection
INSTALLATION AND USE
ƒ STEP 1
All components of the personal fall arrest system must
be selected and deemed compatible with RTFA by a
Competent Person.
ƒ STEP 2
Ensure area where work is to be performed is free of all
hazards, including, but not limited to, debris, rot, rust,
sharp or abrasive edges and surfaces, and hazardous
materials.
ƒ STEP 3
Anchor point must be located above harness D-ring at a
sufficient height to prevent freefall.
STANDARD OVERHEAD USE (ALL VARIANTS)
ƒ Step 4a
Attach RTFA housing to anchor point with provided
karabiner, or equivalent EN362:2004 compliant connector,
and attach lifeline connector to applicable harness D-ring.
Ensure that the hook of the device is secure in the harness
D-ring and that the gate of the hook is locked.
INVERTED USE (W2H & W2TH ONLY!)
ƒ Step 4b
To use RTFA with housing at harness, attach the
anchorage connection point to the dorsal D-ring via the
provided karabiner, dual RTFA bracket or equivalent
EN362:2004 compliant connector, then attach lifeline
connector to suitable anchorage point.
HORIZONTAL USE (ALL VARIANTS)
ƒ Step 4c
The anchor point may only be situated at the same height
as the edge at which a fall might occur or above the edge,
NEVER below. Install the device with a minimum setback
distance of 2.5m from leading edge (C10H, C10HW, C15H
& C15HW).