DIAGRAM A - FALL CLEARANCE
Fall clearance calculation example shown below are based
on a standing worker falling directly in-line with anchor point.
2 m
0,75m
1 m
Swing Fall
Freefall
Maximum Arrest Distance
Harness Stretch
Safety Factor
Swingfall
WARNING!
Eliminate Swing Fall whenever possible!
If swing fall exists, always account for additional fall clearance.
Example above shows deployment distance based on a 1.5m
freefall over a leading edge using a CNB/P/11.060 rated
leading edge RTFA.
14
Up to 1,5m
Up to 2m
0,5m
1m
Swing Fall
DIAGRAM B - CONNECTIONS
DIAGRAM C - LATERAL MOVEMENT
1.5m
1.5m
WARNING!
Limit lateral movements to a maximum 1.5m
either side of the centre axis of the device anchorage point.
WARNING!
Additional ground clearance is required due
to increased arrest distance caused by swing fall as a result
of lateral movement.
Set back