Attention: Hold down the Release button (10) and the Close machine button (11) until the
joining pressure is reached. Then the hydraulic unit shuts off and the buttons can be
released!
The pressure is monitored and automatically regulated again. If the hydraulic system
repumps too often (meaning there is high pressure loss), have it checked.
Put the heating element back in the storage case.
The welding process is ended after the cooling down time has expired, is stored, a signal
sounds and the pressure is dissipated automatically.
Conclude with use of the welding menu by pressing OK.
Dissipate the pressure completely by pressing the button (3).
Unclamp the welded work pieces and remove them.
Move the basic machine apart. The machine is ready for the next welding cycle.
Transferring the log:
This report file should be processed using the ROTHENBERGER Dataline 2 software and a
computer.
All welding parameters can be found in the enclosed welding tables.
3.2.5
Shut-down
Use the button (6) to turn off the hydraulic unit.
Let the heating element cool or stow it in such a way that no adjacent materials can be
ignited!
Remove trimmer unit, heating plate and hydraulic unit mains plugs from power outlet and roll
up cables.
Transport and set the hydraulic unit only in a horizontal position. If it is set at an angle,
oil escapes from the vented plugs with the dipstick!
42
The upper progress bar shows whether the pressure lies within the
correct range (green) or within a permissible (yellow) tolerance range
or whether it lies outside (red) the tolerance range. The time lapse is
shown below. The actual pressure is shown in display (2) and the
remaining joining time in display (9).
In the Log menu item, these can be saved with OK, if a USB stick is
connected. The window then closes automatically.
ENGLISH