NOK
Disable
Screwdriver
OK ALL
Disable
ON/OFF
Screwdriver
SCREW SETTING
Name
Screw Sequence
Screw Name
Screw Reverse
001~250
Sequence 1
001~250
Sequence 2
000~250
Sequence 3
000~250
Sequence 4
000~250
Sequence 5
000~250
OK ALL Holding
Time
OK One Holding
Time
Disable screwdriver when error occurred.
Setting value "1" means the screwdriver will be
Setting value "2" means when two consecutive
errors occurs will lock the screwdriver.
Setting value "3" means when three
consecutive errors occurs will lock the
OFF
screwdriver...and so on. If the tightening status
1~9
is OK once, it will be recalculated,
ON: When malfunction signal "NS" happens, it
will disable screwdriver immediately: User need
to press "ENTER" button to deactivate rotation
(For I/O part. But screwdriver can reverse.)
OFF: When malfunction "NG" happen,
screwdriver will not stop it will not affect next
activation. It will provide a warning.
Disable screwdriver when batch completed
ON: Stop screwdriver after batch completed.
Users need to press "ENTER" (For I/O part, it is
OFF: Screwdriver is normal after batch
Set Up
Value
01~99
******
Setup screw parameter name. It can choose
number, capitals and lower case letters,
0.0~9.9
AT: OK ALL signal holding time
0.0~9.9
1~9
locked when an error occurs.
confirm signal)
completed.
Function Description
Setup screw parameter.
number.
Setup screw reverse strategy
Setup 1
sequence
st
Setup 2
sequence
nd
Setup 3
sequence
rd
Setup 4
sequence
th
Setup 5
sequence
th
OT: OK signal holding time
OFF
OFF
Default setting
01
******
01
01
00
00
00
00
1.0
9.9
49