EGAmaster 66549 Manual De Instrucciones página 62

Ocultar thumbs Ver también para 66549:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

- CLEAR: Click
- CONFIRM: Click
(refer to 66549 User Manual for C3 function introduction).
- DISABLE: Click
- SAVE: Click
- RESET: Click
command is only available in controller)
- ENABLE: Click
- LOAD: Click
- Edit Settings: After entering the system, you must click
password to unlock the screen and switch to other pages.
(Please refer to "Password Change Setting Method")
- Lock Settings: Click to automatically jump to the "Instant data display" screen, and no
operation can be performed. The lock settings must be unlocked.
(Please refer to "Instant data display", "Unlock Settings")
B
Received Data Display: All fastened data can be displayed instantly.
- Received Time: The time to fasten the data.
- Tightening Program: This fastened program group.
- Screw Count: The number of fastened units
- Device Count: The total number of times the device is fastened.
- Tightening Time: How long driver ran before clutch tripped. Sec
- Tightening Torque: the torque for the fastening.
- Tightening Thread: Number of rotations at output shaft.
- Tightening Status: shut off status (OK, NG, OK ALL, REV).
- Device Mode: STD mode, ADV mode please refer to manual
- Device Status: Refer to the "Display Status Code Description" in User Manual
- Barcode Data: Display the barcode data which is from a barcode scanner
62
to reset counting.
to dismiss controller C3 status.
to immediately stop screwdriver operation.
to save the settings into controller.
to restart the controller and restore factory parameters. (This
to immediately allow the screwdriver to run.
to load the settings from the controller.
and enter the

Publicidad

Tabla de contenido
loading

Tabla de contenido