Indel B FLYINGBAR Instrucciones Para El Uso página 36

Ocultar thumbs Ver también para FLYINGBAR:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
FLYING BAR
There are two power supply plugs on the back of the Minibar.
- Connect the "POWER" plug to the socket in the room specifically for the Minibar (socket not con-
nected to the energy saving system).
- Connect the "SIGNAL" plug to any socket connected to the energy saving system (Energy saver).
NOTE: The FLYINGBAR operates in STANDARD/TIMER mode when the "SIGNAL" plug is not
connected. Standard mode refers to operation not relative to identification of the Guest in the
room and operation which is regulated by the temperature selected by the Client using the switch
described above.
WARNING!
If the POWER and SIGNAL cables are connected in reverse, the fridge will operate whilst the guest
is in the room and will switch itself off when the guest leaves the room.
To confirm that the connection is correct, check that the light illuminates when opening the Mini-
bar door subsequent to checking that:
1 ) the energy saving system (Energy saver) is not functioning and that the smart card has not
been inserted
2 ) the Minibar is on (the temperature switch at the front of the Minibar must not be in position "0")
In the instance that the light does not illuminate, invert the connection of the two power cables.
FLYINGBAR_05-06-2020