19. Move the handgrip downwards (), to
achieve the desired working height.
21. Switch on the vacuum generation at the
pressure switch (at the blower unit) ().
23. Place the suction plate always completely on the
load (stone slab). Position the suction plate
always centrally on the load (stone slab) for a
uniform load balancing.
When the suction plate is positioned off center,
there is a risk (when lifting and lowering), that
the load suddenly may fall down. Caused by
uneven load balancing.
Watch the pressure gauge. Once a under
pressure of - 0.22 bar is reached, the load can be
lifted.
Never lift the load before lifting - the load would
fall down.
52400045 / 52400049
20. To lock the handgrip, pull out both spring
bolts a little (right and left of the device)
then turn and release them again until they
engage.
22. The suction of the load (stone slab) as well
as the release is done via the cable plug
(with integrated ON/OFF switch) on the
handle. ().