Replacing The Fuse - ulsonix AIRCLEAN 15000-H20 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 81

REPLACING THE FUSE

CAUTION! The fuse must be replaced by a specialist!
1. Disconnect the unit from the power supply.
2. Disconnect the power cord and remove the fuse holder.
3. To remove the fuse, turn the fuse handlec ounterclockwise.
4. Replace the fuse with a new one of the same rating.
5. Reinstall the fuse holder.
CAUTION! To avoid damaging the fuse holder, do not use excessive force when
removing and installing the fuse holder.
DISPOSAL OF USED UNITS.
At the end of its useful life, this product should not be disposed of with normal
household waste but should be taken to a collection point for the recycling of
electrical and electronic equipment. This is indicated by the symbol on the
product, operating instructions or packaging. The materials used in this unit are
recyclable according to their marking. You will be making an important
contribution to protecting our environment by reusing, recycling or otherwise
disposing of used units.
Your local administration will provide you with information about the
appropriate disposal point for used units.
TROUBLESHOOTING
Problem
The unit does not
work.
The unit is not
working properly.
Possible cause
Improper connection of the
cable to the power outlet.
The plug is not properly
connected to the electrical
outlet.
The electrical outlet does
not work.
The ozone plate is
dirty/cracked.
Blown/incorrectly installed
fuse.
Action
Check that the cord is
properly plugged into the
power outlet.
Check that the plug is
properly connected to the
electrical outlet.
Check that the electrical
outlet is working properly.
Check that the ozone plate is
clean and dry with no cracks.
Any cracks on the ozone
plate can cause visible
lightning and lack of ozone
output.
Check that the fuse is
properly installed and in
good condition.