iNSTallaTiON
installation

10.2 Alternative installation methods

10.2.1 Electrical connection from below on unfinished walls
f Fit the cable grommet.
f
Material losses
!
If you break open the wrong knock-out in the back panel
by mistake, you must use a new back panel.
f Break out the cable grommet knock-out in the back panel.
f
Deburr any sharp edges with a file if necessary.
f Reposition the mains terminal in the appliance from the top
f
to the bottom.
f Push the back panel over the threaded stud and the cable
f
grommet. Pull the cable grommet by the locking hooks into
the back panel using pliers, until both locking hooks audibly
click into place.
f Press the back panel firmly into place and lock the fixing tog-
f
gle by turning it clockwise through 90°.
www.stiebel-eltron.com
10.2.2 Electrical connection on finished walls
f Cleanly cut or break out the required cable entries in the
f
back panel (for positions, see chapter "Specification / Dimen-
sions and connections"). Deburr any sharp edges with a file if
necessary.
f Route the power cable through the cable grommet and con-
f
nect it to the mains terminal.
10.2.3 Connecting a load shedding relay
When operating additional electric appliances, such as electric
storage heaters, install a load shedding relay in the distribution
board. The relay responds when the instantaneous water heater
starts.
1
L1í
2
10.2.4 Water installation on finished walls
f Fit water plugs with gaskets to seal the concealed
f
connections.
f Fit a suitable pressure tap.
f
Note
This type of connection changes the IP rating of the ap-
pliance.
f Change the type plate. Cross out "IP 25" and mark
f
the box "IP 24". Use a ballpoint pen to do this.
Material losses
!
If you break open the wrong knock-out in the back panel
by mistake, you must use a new back panel.
Material losses
!
Connect the phase that switches the load shedding relay
to the indicated terminal of the mains terminal in the
appliance (see chapter "Specification / Wiring diagram").
Note
This type of connection changes the IP rating of the ap-
pliance.
f Change the type plate. Cross out "IP 25" and mark
f
the box "IP 24". Use a ballpoint pen to do this.
PEG |
9